AUTODOME IP starlight 7000 HD Connection | en 77
Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679
AUTODOME Programmed N.O.S.
Contact Alarm Condition
Open Normal
Closed Alarm
Cut or break Tamper
Configuring a Normally Closed Supervised Alarm
1. Install a 2.2 K end-of-line resistor in the alarm circuit.
2. Connect the alarm wires to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the
camera.
2.2K
Figure15.47: N.C.S. - Normally Closed Supervised Connections
1 Dry Contact 3 Dome Connector
2 Alarm 1 or 2 only (Pin 5 or 6) 4 Ground (Pin 7)
3. From Configuration, select Interfaces > Alarm Inputs, select the number of the Alarm
input and finally, select N.C. See the table below for contact and condition details.
AUTODOME Programmed N.C.S.
Contact Alarm Condition
Open Alarm
Closed Normal
Short Tamper
Configuring Non-supervised Alarms (inputs 3 through 7)
You can configure alarms 3 through 7 as non-supervised Normally Open (N.O.) or Normally
Closed (N.C.) alarms.
Configuring a Normally Open Non-supervised Alarm
1. Connect the alarm to the appropriate input (3 through 7) and ground at the camera.
Figure15.48: N.O. - Normally Open Non-supervised Connections