78 en | Connection AUTODOME IP starlight 7000 HD
2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems
2 Alarm Inputs 3 to 7 4 Ground
2. From Configuration, select Interfaces > Alarm Inputs, select the number of the Alarm
input and finally, select N.O. See the table below for contact and condition details.
AUTODOME Programmed N.O.
Circuit Alarm Indication
Open Normal
Closed Alarm
Configuring a Normally Closed Non-supervised Alarm
1. Connect the alarm to the appropriate input (3 through 7) and ground at the camera.
Figure15.49: N.C. Normally Closed Non-supervised Connections
1 Dry Contact 3 Dome Connector
2 Alarm Inputs 3 to 7 4 Ground
2. From Configuration, select Interfaces > Alarm Inputs, select the number of the Alarm
input and finally, select N.C. See the table below for contact and condition details.
AUTODOME Programmed N.C.
Circuit Alarm Indication
Open Alarm
Closed Normal
Alarm Outputs
The camera incorporates two (2) types of alarm outputs: one dry contact relay and three (3)
open collector outputs or transistor outputs.
Configuring a Dry Contact Relay
The dry contact relay acts like an on/off switch. It has a maximum voltage rating of 2A @
30DC.
1. Connect the appropriate stripped wire to the camera’s COM connector.
2. Connect the appropriate stripped wire to the N.O. or N.C. connector, depending on your
requirement.
Configuring an Open Collector Output
Outputs 1, 2, and 3 are open collector types. These outputs must be connected to a positive
voltage between 5 and 32 V to complete the circuit, with a maximum voltage rating of 32VDC
@ 150ma.
1. Connect the appropriate stripped wire to the open connector (1, 2, or 3) of the
transistor.
2. Connect the appropriate stripped wire to the ground (GND) connector.