• Three operating modes: MANUAL, AUTOMATIC, SYSTEM
BYPASS
• Daily programming of both heating and cooling.
• Dual mode functionality: DIFFERENTIAL and
PROPORTIONAL INTEGRAL
• Calibration of measured temperature.
• Automatic advance for reaching the set temperature.
• Remote activation.
• System operating hours count from 1 to 9,999.
• The possibility of timer-controlled manual operation.
• Range of adjustment: from +3 to +35°C
• Temperature levels: three, programmable between +3°C
and +35°C
• Frost Protection temperature: adjustable between +3°C
and +16°C.
• Programming: a temperature level for each hour or each
day of the week which can be extended to two levels by
setting the start-up/shutdown delay time.
• Room temperature measuring interval: 15 seconds:
• Thermal differential: adjustable from 0°C to 0.9°C
• Reading resolution: 0.1°C.
• Displayed reading range: from 0°C to +40°C
• Precision: ≤ ±0.3°C.
• Class A software.
• Degree of pollution: 2.
• Impulse voltage: 4 KV.
• Maximum control unit temperature: 40°C.
• Protection rating: IP30.
• Class II electrical insulation.
Use only ALKALINE batteries
• Operating temperature: from 0°C to +40°C
• Dimensions: see figure 98.