ENGLISH / 28
TROUBLE-
SHOOTING
CAUSES
SOLUTIONS FOR
THE TECHNICIAN
SOLUTIONS FOR
THE USER
The machine is
not dispensing
steam.
• Steam exit hole on the dis-
pensing wand clogged.
• The dispensing channels
could be clogged by scale.
• Clean any deposits on the hole of the dis-
pensing nozzle with a pin.
• Call the Technician to do scale removal.
The machine is
not dispensing
hot water.
• Supply tap off.
• The dispensing channels
could be clogged by scale.
• Turn on the tap and check that the pipes
are in the correct position.
• Call the Technician to do scale removal.
Only for versions with DISPLAY and HYPERWAND:
Only for versions with CAPPUCCINATORE:
Only for versions with BULLONE ROSSO:
Foaming milk is
not coming out
of the cappucci-
no attachment.
• Make sure the suction tube
is in the right position.
• Make sure the cappuccino
attachment is not clogged.
• Make sure the suction tube is immersed
in the milk.
• Carry out the cleaning operations descri-
bed in the paragraph on cleaning.
Limited water
fl ow to the deliv-
ery groups.
Gicleur-holder fi lter of fl ow-
meters obstructed or un-
clean.
Replace.
Contact authorized
service agent
Group(s) not
in temperature
(cold).
Circulation reducers obstruct-
ed.
Clean and replace if
necessary.
Contact authorized
service agent
Result in a cup
not non con-
stant.
Stabilizer heating-element
(added boiler) interrupted or
defected thermostat(s).
Replace.
Contact authorized
service agent
“PUSH STEAM
BUTTON” alarm
The alarm appears at the
end of time, inserted to pro-
gramming, to the last use of
HYPERWAND.
See chapter “CLEANING”.