Braun Infusomat Space P User Manual

Braun Infusomat Space P
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Infusomat® Space P
and Accessories
Instructions for Use
Valid for software 687N
GB
It is recommended that all pumps at
your care unit are equipped with the
same software version or in parallel
use with Software M.
38911866N_Infusomat Space P_GB_060418 LLD Order 3238
Question and Answer IconNeed help?

Do you have a question about the Braun Infusomat Space P and is the answer not in the manual?

Braun Infusomat Space P Specifications

General IconGeneral
ManufacturerB. Braun
ModelInfusomat Space P
Device TypeInfusion Pump
Infusion ModesContinuous, Intermittent
Volume to be Infused (VTBI) Range0.1 ml to 9999 ml
KVO Rate0.1 ml/h to 5 ml/h, selectable
Battery TypeLithium-ion
Battery LifeUp to 8 hours
Power Supply100-240 V AC, 50/60 Hz
DisplayColor Graphic Display
ConnectivityRS232
AlarmsOcclusion, Air-in-line, Low battery
Compatible withSpaceStation
CertificationsCE

Summary

Infusomat Space P Overview

Patient Safety

Intended Use

Defines the specific medical applications and patient populations for which the Infusomat Space P is designed.

General Operation Safety

Details essential safety measures during pump operation, including positioning, inspection, and line management.

Environmental Safety

Covers safety requirements for pump installation in medical rooms and proximity to flammable substances.

Menu Structure and Navigation

Display Examples and Meanings

Illustrates various screen displays and provides detailed explanations of their content and context.

Chapter 1: Operation

1.1 Start of Infusion

Provides step-by-step instructions for correctly initiating an infusion therapy session with the pump.

1.2 Infusion Line Insertion

Details the procedure for correctly inserting the infusion line into the pump's mechanism and sensors.

1.3 Priming and Patient Connection

Explains the process of priming the infusion line and establishing the connection to the patient.

1.5 Rate, VTBI, and Time Entry

Describes how to input and calculate infusion rate, VTBI, and time parameters for therapy setup.

1.6 Bolus Application

Details the methods for administering manual or pre-selected bolus doses of medication.

1.7 Infusion Line Change and New Therapy Start

Guides on safely changing the infusion line and initiating a new therapy session.

1.8 End of Infusion

Outlines the steps required to properly stop an ongoing infusion and conclude therapy.

Chapter 2: Advanced Operations

2.2 Parameter Changes and Data Reset

Details how to modify infusion parameters without interrupting the ongoing therapy and reset status data.

Chapter 3: Special Functions

3.1 Dosing Units and Dose Rate Calculation Overview

Explains the different units used for dosing and the overview of dose rate calculation functionality.

3.2 Dose Rate Calculation Operation

Guides on performing dose rate calculations based on patient weight, height, and drug concentration.

3.3 Drug Library

Covers the management and use of the pump's drug library for storing and recalling therapy data.

3.4 Patient Controlled Analgesia (PCA)

Provides comprehensive instructions on setting up and administering Patient Controlled Analgesia.

3.6 Piggyback Function

Explains how to set up and administer secondary (piggyback) infusions alongside primary ones.

3.7 Ramp and Taper Mode

Details the Ramp and Taper mode for gradual increases and decreases in infusion rate over time.

Starting Ramp and Taper Mode

Guides on initiating Ramp and Taper infusions either via the drug library or special functions menu.

3.8 Program Mode

Covers the Program Mode for delivering infusions with a series of defined intervals and parameters.

Starting Program Mode

Details the steps to start infusions using the Program Mode, either from drug library or special functions.

3.9 Intermittent Mode

Explains the Intermittent Mode, consisting of bolus and rate phases, for specific therapy delivery.

Starting Intermittent Mode

Guides on initiating Intermittent Mode therapies using the drug library or special functions menu.

3.10 Dose Over Time

Describes the Dose Over Time function for administering a specific dose within a set time frame.

Starting Dose Over Time

Provides instructions on how to initiate a Dose Over Time therapy, including setting total dose and time.

Chapter 4: Autoprogramming

Accepting Autoprogrammed Orders

Explains the workflow for accepting drug orders received wirelessly from EHR or SpaceStation.

Chapter 5: Options

5.1 Occlusion Pressure Settings

Details how to adjust the occlusion pressure levels to prevent or manage infusion line occlusions.

Chapter 6: Alarms

Alarm Signal Types

Details the types of audible and optical alarm signals used by the pump, including LED indicators and staff call.

6.1 Device Alarms

Explains actions to take in case of device-specific alarms, including troubleshooting steps.

6.2 Pre-Alarms and Operating Alarms

Differentiates between pre-alarms and operating alarms, their causes, and user responses.

Specific Alarm Messages

Lists common alarm messages, their potential causes, and recommended actions for resolution.

Chapter 7: Battery Operation and Maintenance

Battery Maintenance and Replacement

Explains the cyclical battery maintenance process and how users can replace the battery pack.

Chapter 9: Technical Data

Related product manuals