Elan 10 2.0 / Elan 16 2.0 / Elan 25 2.1 Revision D 21
&KDSWHU)DXOWV
If message E999 appears on the display directly when the ap-
pliance is powered up, the control pcb is not suitable for this
appliance or the dip switches on the control pcb are set incor-
rectly.
For the location of the dip switches on the board, see §10.1.
In that case, check whether the dip switches on the control pcb
are set as shown in the drawing of the dip switch settings; if
they are, and the message E999 still appears, then replace the
control pcb by a pcb of the correct type.
How to access the pcb is described in §9.2 item 1 - 6.
8.1 Trouble shooting
When the appliance control system detects a fault, it is indi-
cated on the display with a spanner symbol, possibly together
with a fault code.
The appliance makes a distinction between a fault at which the
DSSOLDQFHNHHSVUXQQLQJOLPLWHGO\DQGDVHULRXVORFNLQJIDXOW
at which the fan is switched off.
In case of locking fault, the settings and readings menu is swit-
ched off as well and only the service menu is available.
The appliance remains in this fault mode until the problem in
question has been solved. Then the appliance will reset itself
DXWRUHVHWDQGWKHGLVSOD\ZLOORQFHPRUHVKRZWKHRSHUDWLQJ
mode.
Fault E999
Locking fault
When the appliance detects a locking fault, it will no longer
ZRUN7KHSHUPDQHQWO\OLJKWHGGLVSOD\VKRZVWKHIDXOWV\PERO
VSDQQHUWRJHWKHUZLWKDIDXOWFRGHVHHWDEOHQH[WSDJH7KH
UHG/('RQWKHPXOWLSOHVZLWFKLIDSSOLFDEOHZLOOEHEOLQNLQJ
Contact the installer to remedy this fault. A locking fault cannot
EHUHPHGLHGE\WDNLQJWKHYROWDJHIURPWKHDSSOLDQFH¿UVWWKH
fault must be solved.
8.2 Display codes
Non-locking fault
When the appliance detects a non-locking fault, it will still keep
UXQQLQJ OLPLWHGO\ 7KH GLVSOD\ GRHV VKRZ WKH IDXOW V\PERO
VSDQQHU
Elan 10 2.0
Elan 16 2.0
ON
Elan 25 2.1
ON
ON