ALARM
ALARM ALARM
ALARM
CODE
CODECODE
CODE
DESCRIPTION
DESCRIPTIONDESCRIPTION
DESCRIPTION
PROBLEM
PROBLEMPROBLEM
PROBLEM
PROBABLY SOLUTION
PROBABLY SOLUTIONPROBABLY SOLUTION
PROBABLY SOLUTION
AL1 BACK OUT THE STOVE IS TEMPORALY
WITHOUT ELECTRICAL
CURRENT
Press the key nº 4 for some seconds and let
finish the final cleaning. The stove will come
back to the shut down mode.
AL2 SMOKE PROBE PROBLEM ON THE SMOKE
PROBE
Check the probe connexion or replace it.
AL3 SMOKE TEMP. SMOKE TEMPERATURE IS
ABOVE 270º C
Regulate the pellet fall and/or extractor
speed. Verify the kind of fuel used.
AL4 BROKEN
DOWN
EXTRACTOR
PROBLEM ON THE SMOKE
EXTRACTOR
Check the extractor electrical connexion or
replace it.
AL5 STARTING UP
FAILURE
THE PELLET FUEL DOES NOT
FALL AND BURN UP
Check the gearmotor operation and the
resistor. Check a probably blockage on the
worm screw. Check there are pellet on the
hopper.
AL6 NO PELLET THERE IS NO PELLET ON THE
HOPPER OR DO NOT FALL
INTO THE BURNER POT
Fill the hopper. Check the worm screw
operation. Check the pellet length and if it is
caked. Clean the back of the hopper.
AL7 THERMAL
ALARM
THE PELLET SAFETY
THERMOSTAT HAS GONE
OFF
Rearm manually the thermostat. Check the
reason why the excess temperature has
caused the overheating (pellet fall, chimney
excess, type of fuel, tangential turbine
operation).
AL8 DEPRESSION THE COMBUSTION CHAMBER
IS ON DEPRESSION
Verify the combustion chamber is hermetic:
check the locks, hermetic joints…etc. Check
the accurate gas expulsion installation
(excess of horizontal flights, elbows…etc).
Probably pellet blockage.