2-83
Confidential
■ Error code E000
Some ROM checksum error occurred.
Error code E100
Program error.
< User Check >
- Install the latest firmware.
■ Error code E400
The failed DIMM is installed, or the DIMM is not installed correctly.
< User Check >
- Install the DIMM correctly.
- Install the latest firmware.
■ Error code E500
Error occurred when DRAM on the main PCB ASSY was accessed.
Error code E600
Error occurred during writing to EEPROM on the main PCB ASSY.
Error code E702
Error occurred during reading from the flash ROM on the main PCB.
Print Unable E0
Turn off and on.
Print Unable E1
Turn off and on.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Print Unable E4
Turn the power off and then back on again.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Print Unable E5
Turn the power off and then back on again.
Print Unable E6
Turn the power off and then back on again.
Machine Error E7
Turn off and on.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.