5-22
Confidential
1.3.12 Changing return value of USB No./Switching Dither Pattern/
Switching of ON/OFF of DirectPrint Color mode-Improve Gray Color/
Switching of timing to execute Auto Registration/
Adjusting left-end print start position on second side in duplex printing/
Change of the transfer current setting/Change of ghost reduction setting
(Function code 45)
■ Changing return value of USB No.
<Function>
When the operating system (OS) installed on the computer is Windows Vista
®
, and the
machine is connected to this computer using USB2.0FULL, the OS may not be able to obtain
the USB device serial number depending on the computer and USB device. If the serial
number cannot be obtained, the number of devices increases each time the device is
connected to the computer. To avoid this problem, setting this function to “USBNo.=ON” can
fix the USB No. return value to “0”.
“*” is displayed at the end of the currently specified function in the LCD display.
<Operating procedure>
LCD Description
USBNo. =ON Returns “0”.
USBNo. =OFF Returns the serial number of the machine. (default)
Model without touch panel
Model with touch panel
(1) Press the or key to display
“MAINTENANCE 45” on the LCD in the
initial state of the maintenance mode.
Then, press the OK key. “USBNo.” is
displayed on the LCD.
(2) Press the OK or Go key. “USBNo.=ON”
is displayed on the LCD.
(3) Press the or key to select
“USBNo.=ON” or “USBNo.=OFF”, and
press the OK or Go key.
(4) “Accepted” is displayed on the LCD,
and the machine returns to the initial
state of the maintenance mode.
(5) Turn OFF the power switch of the
machine.
(1) Press the 4 and 5 keys in this order in
the initial state of the maintenance
mode. “USBNo.” is displayed on the
LCD.
(2) Press the Mono or SET key.
“USBNo.=ON” is displayed on the LCD.
(3) Press the or key to select
“USBNo.=ON” or “USBNo.=OFF”, and
press the Mono or SET key.
(4) “Accepted” is displayed on the LCD,
and the machine returns to the initial
state of the maintenance mode.
(5) Turn OFF the power switch of the
machine.
Note: