Loading...
2-54
Confidential
Error code 5001
Number of used pages for the PF kit MP has reached the upper limit. (Printing is not stopped.)
Error code 5002
Number of used pages for the PF kit 1 has reached the upper limit. (Printing is not stopped.)
Error code 5003
Number of used pages for the PF kit 2 has reached the upper limit. (Printing is not stopped.)
Replace PF Kit MP
-
Step Cause Remedy
1 The PF kit MP is at the end of life Replace the PF kit MP. After replacing the
PF kit MP, refer to “1.3.29 Reset counters
for parts (Function code 88)” in Chapter 5,
and reset the PF kit MP counter.
2 Main PCB failure if the error code
remains after resetting the
counter of the PF kit MP
Replace the main PCB ASSY.
Replace PF Kit1
-
Step Cause Remedy
1 The PF kit 1 is at the end of life Replace the PF kit 1. After replacing the
PF kit 1, refer to “1.3.29 Reset counters
for parts (Function code 88)” in Chapter 5,
and reset the PF kit 1 counter.
2 Main PCB failure if the error code
remains after resetting the
counter of the PF kit 1
Replace the main PCB ASSY.
Replace PF Kit2
-
Step Cause Remedy
1
The PF kit 2 is at the end of life Replace the PF kit 2. After replacing the
PF kit 2, refer to “1.3.29 Reset counters
for parts (Function code 88)” in Chapter 5,
and reset the PF kit 2 counter.
2
Main PCB failure if the error code
remains after resetting the
counter of the PF kit 2
Replace the main PCB ASSY.