Confidential
5-40
5.1.18 Fixing Unit
(1) Disconnect the heater harness connector and thermistor harness connector.
(2) Remove the two cup B M4x12 taptite screws, and then remove fixing unit.
NOTE: Be sure not to touch the pressure roller.
(3) Remove the two PR spring.
(4) Remove the pressure roller ASSY (pressure roller, PR arm ASSY, PR bush) from the fuser
frame.
Taptite, cup B M4x12
Fixing uni
Taptite, cup B M4x12
Heater harness
1
3
2
Thermistor harness
PR a
ASSY
Hoo
PR spring
Pressure rolle
PR spring
Hoo
PR a
ASSY
Fuser frame
“
”
“
”
Hoo
PR spring
“
”
3
2
2
1