8-2 Confidential
8.2 LIST OF MAINTENANCE-MODE FUNCTIONS
Maintenance-mode Functions
Function
Code
Function
Reference
Section (Page)
01 EEPROM Parameter Initialization 8.4.1 (8-5)
05 Printout of Scanning Compensation Data 8.4.2 (8-6)
08 ADF Performance Test 8.4.3 (8-8)
09 Test Pattern 8.4.4 (8-9)
10 Firmware Switch Setting 8.4.5.1 (8-10)
11 Printout of Firmware Switch Data 8.4.5.2 (8-12)
12 Operational Check of LCD 8.4.6 (8-13)
13 Operational Check of Control Panel PCB 8.4.7 (8-14)
16 Adjustment of Handset Volume 8.4.8 (8-15)
32 Sensor Operational Check 8.4.9 (8-16)
53 Received Data Transfer Function 8.4.10 (8-17)
54 Fine Adjustment of Scan Start/End Positions 8.4.11 (8-19)
55 Acquisition of White Level Data and CIS Scanner Area Setting 8.4.12 (8-21)
67 Continuous print Test 8.4.13 (8-21)
74 EEPROM Customizing 8.4.14 (8-22)
80 Display of the Equipment’s Log Information 8.4.15 (8-23)
82 Machine Error Code Indication 8.4.16 (8-25)
87 Output of Transmission Log to the Telephone Line 8.4.17 (8-25)
99 Exit from the Maintenance Mode
Cancellation of the Memory Security Mode 8.4.18 (8-25)