5-14
5.1.11 Panel Unit
(1) Disconnect the panel harness.
(2) Remove the panel unit.
(3) Remove the cup B M3x6 taptite screw to remove the separation rubber, ADF plate spring
and front plate spring.
Panel uni
t
Main PCB
Connecto
r
ADF plate spring
Front plate spring
Separation rubbe
r
Tapti
t
, cup B M3x6
Panel uni
t
1
2