4-9
Confidential
3. IF YOU REPLACE THE HIGH-VOLTAGE
POWER SUPPLY PCB ASSY
<What to do when replacing the high-voltage power supply PCB ASSY>
- Sensitivity adjustment of density sensor (Maintenance mode: code 72)
- Performing the developing bias voltage correction (Maintenance mode: code 83)
- Performing the adjustment of inter-color position alignment (Maintenance mode: code 66)
3.1 Sensitivity Adjustment of Density Sensor
(Maintenance Mode: Code 72)
Make sensitivity adjustments of the density sensor in accordance with "1.4.25 Sensitivity
adjustment of density sensor" in Chapter 5.
3.2 Performing the Developing Bias Voltage Correction
(Maintenance Mode: Code 83)
Perform developing bias voltage correction in accordance with "1.4.31 Developing bias
voltage correction" in Chapter 5.
3.3 Performing the Adjustment of Inter-color Position
Alignment (Maintenance Mode: Code 66)
Perform adjustment of inter-color position alignment in accordance with "1.4.19 Adjustment of
inter-color position alignment" in Chapter 5.