INSPECTION AND MAINTENANCE60
10
3. Connect a water hose. Turn on the
water and adjust the flow.
4. Put the shift lever in the neutral position
and start the engine.
Continue flushing the outboard motor
for 3 to 5 minutes at idling.
5. Stop the engine and water supply.
Remove the flushing attachment and
tape.
6. After the flushing, be sure to reattach
the water plug.
.
1. Flushing attachment
ENOM00085-A
Flushing by test tank
ENOW00081-0
Do not start engine without removing pro-
peller, or accidentally turning propeller
could cause personal injury.
ENOW00082-0
Never start or operate the engine indoors
or in any space which is not well ventilated.
Exhaust gas contains carbon monoxide, a
colorless and odorless gas which can be
fatal if inhaled for any length of time.
ENOW00036-A
When the engine is started in the test tank,
to avoid over heating and water pump
damage, be sure the water level is at least
10 cm (4 in.) above the anti ventilation
plate.
And be sure to remove the propeller, when
starting the engine in the test tank. (See
page 68)
1. Over 10 cm (4 in.)
ENOM00950-0
Fuse replacement
ENOW00923-0
Before replacing a fuse, disconnect the
battery cable from the battery negative (-)
terminal. Failure to do so may cause a
short-circuit.
ENOW00924-0
Never use a fuse with a rating that exceeds
the specified rating as this could cause
serious damage to the electrical system.
If a blown fuse is detected, try to deter-
mine the cause for this and correct it. If the
cause for the problem is not corrected, the
WARNING
WARNING
ENOF01223-0
1
CAUTION
CAUTION
CAUTION
1
ENOF00863-0