EasyManuals Logo

Bryant Preferred Series User Manual

Bryant Preferred Series
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
70
Fig. A — Model Number Nomenclature
Unit Type
581 = High Efficiency
Gas Heat RTU
Model
J = Puron Refrigerant
Voltage
E = 460-3-60
P = 208/230-3-60
T = 575-3-60
Cooling Tons
17 - 15 ton
20 - 17.5 ton
24 - 20 ton
28 - 25 ton
Refrig. System/Gas Heat Option
D = Two Stage Compressor Model
F = Two Stage Compressor Models and
Stainless Steel Gas Heat Exchanger
K = Two Stage Cooling with Aluminum
Gas Heat Exchanger and Perfect Humidity*
M = Two Stage cooling with Stainless Steel
Gas Heat Exchanger and Perfect Humidity*
Heat Level Input
220 = 220,000
310 = 310,000
400 = 400,000
Packaging, Controls and Indoor Fan Motor
Speed Options
A = Standard Packaging, electro mech. controls that
require W7212 EconoMi$er IV
C = Standard Packaging, electro mech. controls that
require W7220 EconoMi$er X
D = Standard Packaging and 2-Speed Indoor Fan Motor
(VFD) Controller
Outdoor Air Options
A = None
B = Temp Econo, Baro Relief, Low Leak (W7212 or W7220)
D= Temp Econo, Cent Power Exhaust, Low Leak (W7212 or W7220)
E = Temp Econo, Baro Relief, Low Leak w/ CO (W7212 or
W7220)
H = Enthalpy Econo, Baro Relief, Low Leak (W7212 or W7220)
K = Enthalpy Econo, Cent Power Exhaust, LowLeak (W7212 or
W7220)
G = Temp Econo, Cent Power Exhaust, Low Leak w/ CO (W7212 or
W7220)
L = Enthalpy Econo, Baro Relief, Low Leak w/ CO (W7212 or
W7220)
N = Enthalpy Econo, Cent Power Exhaust, Low Leak w/ CO (W7212 or
W7220)
Q = Motorized 2 Position Damper
P = Manual Outdoor Air Damper
U = Temp Econo, Baro Relief, Ultra Low Leak, (W7220)
V = Temp Econo, Cent Power Exhaust, Ultra Low Leak (W7220)
W = Enthalpy Econo, Baro Relief, Ultra Low Leak, (W7220)
X = Enthalpy Econo, Cent Power Exhaust, Ultra Low Leak (W7220)
Indoor Fan Options
1 = Standard Static Option, Vertical
2 = Medium Static Option, Vertical
3 = High Static Option, Vertical
B = Medium Static, High Efficiency Motor, Vertical
C = High Static, High Efficiency Motor, Vertical
5 = Standard Static Option, Horizontal
6 = Medium Static Option, Horizontal
7 = High Static Option, Horizontal
F = Medium Static, High Efficiency Motor, Horizontal
G = High Static, High Efficiency Motor, Horizontal
Coil Options (Outdoor – Indoor – Hail Guard)
A = AI/Cu – AI/Cu
B = Precoat AI/Cu – AI/Cu
C = E-coat AI/Cu – AI/Cu
D = E-coat AI/Cu – E-coat AI/Cu
E = Cu/Cu – AI/Cu
F = Cu/Cu – Cu/Cu
M = AI/Cu – AI/Cu – Louvered Hail Guards
N = Precoat AI/Cu – AI/Cu – Louvered Hail Guards
P = E-coat AI/Cu – AI/Cu – Louvered Hail Guards
Q = E-coat AI/Cu – E-coat AI/Cu – Louvered Hail Guards
R = Cu/Cu – AI/Cu – Louvered Hail Guards
S = Cu/Cu – Cu/Cu – Louvered Hail Guards
5 8 1 J E 1 7 D 3 1 0 A 1 A 0 A A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Factory Installed Options
0A = None
Not all possible options can be displayed above - see price pages or contact your Bryant Sales representative for more details
*Units equipped with Perfect Humidity System include Motormaster controls.
APPENDIX A — MODEL NUMBER NOMENCLATURE

Table of Contents

Other manuals for Bryant Preferred Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant Preferred Series and is the answer not in the manual?

Bryant Preferred Series Specifications

General IconGeneral
BrandBryant
ModelPreferred Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals