Manual EVOTOUCH v.5 85 / 104
Automatic
Select this mode only if you have an ADVANCED probe Kit (Redox) or
PRO/2 amperometric kit. If you do not have a probe, the equipment will
have a random behaviour and end up by stopping and showing an error.
This mode has an automatically adjust chlorine level of your swimming pool.
Based on the adjusted set value in the "chlorine" menu, the equipment will stop
when it reaches this value, and start-up again automatically when there is a
need for chlorine.
At the bottom line of this menu, there is a CL+ORP button. By enabling this
switch, free chlorine and ORP measures will be shown at the Main Screen. In
case on probe is unavailable, this feature will allow to choose which one should
be displayed in the Main Screen
4.1.2.3 Free Chlorine Menu
Free Chlorine set point can be setup in this menu, when Automatic mode is
selected and Pro/2 Kit is installed. Calibration is also available in this menu.
In this case, the ppm value can be adjusted within a 0-10ppm range. The
optimum range is from 1ppm to 2ppm.
NOTE: When Automatic mode is selected, production set point can be changed.
4.1.2.3.1 Calibration
1) Install the probe on the probe holder. Use a tool to ensure the sensor
is correctly tightened.
2) Switch on the filtration pump and adjust the water flow. The red flow
indicator must be floating in the mid part of the indicator: