This parameter is calculated based on the values of electrical current and voltage in the electrolysis cell,
together with the water temperature.
The result is displayed at the bottom of the main screen, as shown in the image below.
Please take note of the following considerations regarding the indirect measurement of salt
concentration:
The salt calculation will appear on screen only if an NTC/1 kit is installed, since this kit is in charge
measuring the water temperature, necessary for the calculation.
This value gets updated once the chlorine production percentage reaches 100%.
When this percentage is less than 100%, the chlorinator will show the latest salt concentration value
calculated and that value will remain until the production reaches 100% again.
If the production setpoint is lower than 100%, the system will update the salt concentration
measurement during the automatic cleaning cycles, where production will eventually reach 100%.
When the system is powered off, the latest measurement of salt will be erased and you will see “—“
upon power on, until production reaches 100% for the first time to make the calculation again.
Important: Salt concentration measurements are trustworthy only if the cell is in good conditions. If the
cell is worn out or with overlay, the value displayed could differ from the actual salt concentration in the
water.