3.2.4- ADVANCED kit (Redox) (OPTIONAL)
The equipment continuously measures the bactericide level of water through this probe, by means of a
"Redox" probe. Simply adjust the required level and the equipment automatically maintains the level of
disinfection by adjusting the production of chlorine to the real needs of the swimming pool.
The screen shows the "Redox" level (bactericide capacity) present in the swimming pool.
The potential RedOx (Reduced Oxidation) or ORP (Oxidation Reduction Potential) is the electrical voltage
that indicates the oxidation capacity or reduction of a solution. In swimming pools, the oxidation capacity
is directly related to the bactericide power of the water, which is directly related to the concentration of
free chlorine in the pool.
This probe enables you to adjust the equipment in AUTOMATIC operating mode.
3.2.4.1- Parts
1. REDOX Probe
2. Probe-Holder
3. Flange
4. Standard liquid 465mV.
3.2.5- PRO kit (free chlorine) Optional in PRO50-150 equipment
The amperometric measurement kit, allows to obtain a ppm free chlorine Reading from your swimming
pool. This sensor is based in a 3-electrode header, which is separated from the water through a
membrane. This ppm measure has a low dependency of pH and isocyanuric acid, and it can be also
installed in sea water swimming pools (this option to be asked to BSV Electronic). Please follow carefully
the installation, calibration and maintenance instructions to ensure a perfect setup of the kit.
3.2.6- NTC/1 kit (OPTIONAL) for PRO equipment
The temperature probe kit enables you to take a reading of the water temperature. Once the probe has
been connected, the temperature will be displayed in the main screen.
By installing this kit, you will also be able to use the semi-automatic control mode. More details on this
mode can be found on page 60 of this manual.
1-NTC prove
2- Probe-Holder
3-Flange
3.2.7- Measurement of salt concentration in the PRO systems (only in PRO50 and PRO70)
When an NTC/1 probe kit is installed in the chlorinator, the salt concentration measurement feature is
enabled automatically.