4.1.5- Chlorine menu
With this menu you can select all parameters related to chlorine production.
4.1.5.1- Production of cl.
Configuration of the maximum production of chlorine.
From 0% to 100% Press “OK” and use the arrows to change the value. Press "OK" to confirm the
adjustment.
Note: Chlorine production may be limited regardless of the operation mode (manual, automatic...) that is
selected.
4.1.5.2- Adjustment of the set value (Max. ORP or Max. PPM) ORP Mode in which a Redox probe
(OPTIONAL) is installed.
In this case, adjust the oxidation potential to the required level. For private swimming pools that are not
used frequently, 650 mV is a sufficient value 700 mV is the suitable value for the majority of swimming
pools. Press "OK" to confirm the adjustment. However, the best way to adjust the optimal ORP value is
to analyze the water and determine the ratio between ORP and PPM, because there are some
differences between several types of water.
NOTE: if working in automatic, you can also adjust the production percentage from 0% to 100%,
PPM Mode in which a free chlorine probe (OPTIONAL) is installed.
In this case, adjust the value in ppm as required. A value between 1ppm and 1.5ppm is correct.
NOTE: if working in automatic, you can also adjust the production percentage from 0% to 100%,
On connecting the equipment in automatic mode, the ORP/PPM value will flash for 5 min before the
equipment starts to produce chlorine.
4.1.5.3- Super chlorination
Select this option if you require super-chlorination of your swimming pool, bearing in mind the following:
If the equipment is working in semi-automatic mode (with the NTC PROBE KIT ), the equipment will
calculate the time necessary depending on the volume and Temperature. The filtering time to
perform super-chlorination will be displayed on the screen.
Without a Temperature probe, super-chlorination will be carried out for 24 hours. If filtration is stopped,
super-chlorination is suspended.
4.1.5.4- Calibration of the free chlorine probe
If you have a free chlorine probe, a menu will appear for you to calibrate it.