EasyManua.ls Logo

BSV PRO50 - 8- Clock; Warning Messages and Alarms; 1- Warnings

BSV PRO50
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
67 / 72
Manual PRO50-150 V.6
4.1.7.3- Program (2/24h)
This allows two individual daily programs.
4.1.7.4- Program OFF
Cancels and details the programs carried out.
4.1.8- Clock
The equipment has a time clock, which will be taken as the reference when programming times of the
auxiliary relay. The clock keeps the time setting even when the equipment is without supply.
4.2- Warning messages and alarms (PRO)
In the event of abnormal operation, the PRO series equipment will display an alarm message on the 4th
line of the screen, together with an acoustic warning. The alarms shutdown the equipment until the
problem is solved.
Similarly, it will display a warning also in the 4th line, but without an acoustic signal or shutting down
the equipment. In this case, the equipment can continue operating, although you are informed that
corrective action should be taken.
4.2.1- Warnings
Message:
Causes:
Action required:
"LACK OF SALT"
Lack of salt in the water.
Add salt to the swimming pool.
Incrustations or objects in
the electrolysis cell causing lack
of current.
Clean the cell.
The electrolysis cell is worn.
Replace the electrolysis cell with a
new one.
"EXCESS SALT"
Excess salt in the water.
No action required if excess is not
very significant.

Related product manuals