68 / 72
Manual PRO50-150 V.6
Incrustations or objects in
the electrolysis cell causing
excess current.
Clean the cell.
"CLEANING"
The chlorinator is in the self-
cleaning process. The process
lasts 5 minutes
None.
"TEMPERATURE".
The ambient temperature is
>40º
Try and place the equipment in
another position where it is not over
40º or perform forced ventilation.
Leave the equipment to rest
for a few
minutes.
Consult section number
4. Installation
The radiator fins are
obstructed or are not in a
vertical position.
Place the equipment so that air is
circulated for correct cooling.
4.2.1.1- Additional warning messages
ORP or
flashing
PPM
value
is
The redox or free chlorine
probe are balanced in
automatic mode. When the
probe
is balanced, the value
remains set.
None.
pH value is flashing
The pH probe
is balancing.
When the probe is
balanced, the value remains
set.
None.
Value ---o (Water
temperature) is
flashing
The value of the water
temperature
is under
15º.
Consider the use of a
winter
hibernator product.
Filter time
The equipment has
switched off before
the
time
set in semi-
automatic
Restart the filtering cycle