69 / 72
Manual PRO50-150 V.6
4.2.2- Alarm Messages
In
the following cases, the chlorinator shuts down and the alarm and
acoustic alarm LED is
activated
(automatic reset once the fault is solved):
"NO WATER FLOW"
Excess gas in the electrolysis
cell. It may have occurred
because the pump has
shutdown. The gas is hydrogen
gas which is highly flammable.
The piping should be drained to
eliminate gas or accumulated water.
Check the pump.
Sensor cable of the cell is
incorrectly
connected
or
broken.
Check
cable)
the
sensor cable
(white
Cell sensor is dirty.
Clean.
See maintenance.
No water flow
Check the water system
"SHORT CIRCUIT"
The cell
connected.
is
incorrectl
y
Check wiring.
Metal body in the cell.
Turn off the equipment and remove
the metal body from the plates
"OPEN CIRCUIT"
Cell is
connected.
incorrectly
Check the cell connection and ensure
that cables and
connection terminals are in good
condition.
Cell is damaged or
completely worn
down.
Check the condition of the cell
electrodes, and replace it if any
damage is observed.
Swimming pool water with very
low salt
concentration.
Ensure that the water has salt and that
it is dissolved.
"Chl Alarm"
Chlorine
incorrectly
damaged
probe is
connected
or
Check the cabling of the probe and the
probe itself. Check 5.1. It can work in
manual mode if
necessary.
Water contains very low redox
potential.
Leave the equipment to chlorate in
manual mode for at least 2 hours.
Check the chemical
balance of the
water. (appendix
1)
The equipment does not
have a probe and is in
"automatic mode".
Install a Redox or Free Chlorine
probe,
or configure
"manual"
mode.