7 – 34 Repair manual SWE100, 120, 120L, 120S, 140, 140L, 200D © BT
Troubleshooting
Digital input/output status
T code Valid from serial no. Date Order no.
841×842×843 6061850- 2012-08-30 258946-120
Set points
Function: Pos 1 Pos 2 Pos 3 Pos 4
- * * A * Not assigned
Main contactor [Q10].
OUT. MAIN CONTACTOR
* * B * On: Contactor closed
Off: Contactor open
- * * C * Not assigned
Parking brake [Q1]
OUT. BRAKE RELEASE
* * D * On: Brake released
Off: Brake applied
- * * E * Not assigned
Pump motor [M3] active * * F * On: Active
Off: Not active
Proportional valve [Q4] * * G * On: Affected
Off: Not affected
- * * H * Not assigned
Pump contactor [Q25].
OUT. PUMP CONTACTOR
1
1.Only applies to SWE100.
* * * A On: Contactor closed
Off: Contactor open
Fork valve [Q22]
OUT. FORK VALVE
2
2.Applies only to SWE120L, 140L and 200D.
* * * B Not assigned
Support arm valve [Q23]
OUT. SUPPORT ARM VALVE
2
* * * C Not assigned
Spare
(Digital out 4)
* * * D Not assigned
- * * * E Not assigned
- * * * F Not assigned
- * * * G Not assigned
- * * * H Not assigned
A
B
C
D
E
F
G
H