EasyManua.ls Logo

Bucher C-LRV 700 - Technical Data

Default Icon
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLRV lift control valve Product description
28/92
300−I−9010212−E−10/08.08
1.5.2 Technical data
300−1−10008856
110
100
100
110
M4
812
151.7
Weight 0.675kg
Mains voltage NTA−2/115 100/(110)115/120VAC
NTA−2/230 220/230/240VAC ±10%
NTA−2/400 380/(400)415/440VAC
Frequency 50/60Hz ±10%
Power consumption 20W during travel,
approx. 8W at standstill
EMC standards EN−50081, EN−50082, EN−50011/22, IEC 1000−4
Protection class IP 00
Relay contacts
l
min
= 10mA
l
max
= 3A
Command inputs
Command present U < 2.5V
Command current 6mA
Command not present U > 10V