C−LRV lift control valve Operation
87/92
300−I−9010212−E−10/08.08
5.3.3 Code for further details
Code Meaning
Monitoring
101 Constantly
102 At standstill
103 At start of travel
104 During travel
105 Not monitored during inspection travel
106 When the program is started
107 Dependent on parameterisation
Effect
201 Travel is disabled
202 Travel is aborted (relay is opened)
203 Travel is aborted (relay is NOT opened)
204 Travel is aborted (dependent on parameterisation, relay may be opened)
Save
301 If at standstill, immediately; if travelling, at end of travel
302 Delay of 2s
303 Is not saved during inspection travel
Reset
401 Immediately (save only)
402 Delay of 2
403 When the cause has been removed
404 If the "Relay function" setting is "only SIU": reset operation after there is no longer any travel
command. Otherwise: delay of 2s