CLRV lift control valve Operating controls and indicators
40/92
300−I−9010212−E−10/08.08
e.g.
K1−K8 1100 0000
C: +3.45 F: +4.18
Display during travel
S 1st line: status of command inputs K1 to K8
0: no command
1: command is present
S 2nd line: existing control voltage (C) and
feedback value (F) in volts
e.g.
Fast speed ^
7.50 V
Display during parameterisation
S 1st line: parameter name
S 2nd line: value of parameter, including unit
e.g.
1) Err:SIU−1
1x 51965 h
Fault code
S 1st line: fault memory read−out, fault
description
S 2nd line:total number of occurrences of this
fault; last occurrence was at operating
hours h