31
Packaging, transport, storage
Cable gland:
→ Open the Pneumatic Control Unit: unscrewing the transparent
capinananticlockwisedirection.
→ Unscrew the screw terminals and pull out cables.
3. Mechanical connection
→ Loosenthefasteningscrews.
→ RemovethePneumaticControlUnitupwards.
Pneumatic
Control Unit
Transparent cap
Fastening screws
(2x)
Pneumatic
connections
Pneumatic con-
nection to the
actuator
Actuator
Cable gland
Series 21xx
Series 20xx
Fig. 28: Disassembly the Pneumatic Control Unit
13. PACKAGING, TRANSPORT,
STORAGE
NOTE!
Transport damages.
Inadequately protected equipment may be damaged during
transport.
▶ Duringtransportationprotectthedeviceagainstwetanddirt
inshock-resistantpackaging.
▶ Avoidexceedingordroppingbelowthepermittedstorage
temperature.
▶ Protecttheelectricalinterfacesandthepneumaticconnec-
tionsfromdamagebyplacingprotectivecapsonthem.
Incorrect storage may damage the device.
▶ Storethedeviceinadryanddust-freelocation!
▶ Storagetemperature-20...+65°C(-4...+149°F).
Damage to the environment caused by device components
contaminated with media.
▶ Dispose of the device and packagingin an environmentally
friendlymanner.
▶ Observeapplicableregulationsondisposalandtheenvironment.