Defines signal words and pictograms used for hazard classification and warnings.
Covers instrument warnings and conventions for understanding the instruction manual.
Describes the DIGIFORCE® 9311's purpose for monitoring repetitive production processes.
Provides contact details and support information for inquiries and repairs.
Outlines storage and operating requirements for temperature, humidity, and environment.
Specifies requirements for trained personnel, unpacking, and package contents.
Explains the DIGIFORCE® 9311's capability to monitor and analyze process variables.
Covers power supply requirements and compatible sensor types.
Details starting, stopping, and sampling measurement data acquisition.
Lists and explains graphical elements for OK/NOK classification of curves.
Explains the meaning of device status indicators for operation and errors.
Details the power connector pinout and voltage requirements for the unit.
Describes the PLC control signals, opto-isolation, and logic used for interface.
Explains pin assignments for Connector A (potentiometric/standard sensors).
Covers USB service and Ethernet ports for configuration and data retrieval.
Provides instructions for mounting and removing the unit on a 35 mm DIN rail.
Introduces the PC software for configuration and data management.
Guides users on connecting the DIGIFORCE® 9311 to PC software via USB or Ethernet.
Explains how to view and set device information like serial number and software versions.
Covers basic setup, measurement programs, channel settings, and I/O assignments.
Allows viewing live sensor values and adjusting reading resolution.
Explains how to use tare buttons or PLC signals to zero live sensor values.
Retrieves live PLC I/O states and allows manual setting/resetting of PLC outputs.
Lists potential error messages during boot-up and provides troubleshooting advice.
Supports manual retrieval, display, analysis, and export of measurement curves.
Retrieves up to 50 recent measurements, allowing display and export.
Enables automatic data logging and configuration via DigiControl software.
Provides instructions for downloading and saving device settings as a backup.
Guides users on overwriting settings with data from a previously created backup.
Illustrates signal sequences for changing measurement programs with/without acknowledgment.
Depicts measurement cycles with/without data logging and via USB stick.
Shows cycles for external tare with and without monitoring the warning limit.
Explains window evaluation with online signals and switching signals S1 to S6.
Details how to update device and Fieldbus firmware via USB and PC software.
States compliance with EN 61326-1:2013 for interference immunity and emission.
Refers to the data sheet for details on DigiControl PC software versions.