12.2 Type label
The type label serves as product identifier. In case
of any requests, please have the following infor-
mation ready:
1. Device name
2. Order-no.
3. Serial number
Note: The type label is an official document and
must not be altered or stripped off. Dama-
ged or unreadable type labels have to be
replaced.
IMPORTANT NOTICE:
FOR THE CORRECT OPERATION AND MAINTENANCE OF THIS PRODUCT,
IT IS ESSENTIAL TO OBSERVE THE MANUFACTURER'S INSTRUCTIONS.
For further information please visit www.reece.com.au
Type: 1 1/2" 2“
Nominal Size: DN40 DN50
Flow rate (litres per min):
Δp=20 kPa m³/h 10 10
Δp=50 kPa m³/h 16 16
Pressure Loss:
@ 200 kPa: 2,5 2,5
@ 500 kPa: 4,5 4,5
Nominal Pressure (kPa): 1600 1600
Recommended Operating
Pressure Range (kPa): 300-600 300-600
Filter Efficiency (Micron): 90-110 90-110
Operating Temperature (°C):
Water 5-30 5-30
Ambient 5-40 5-40
Power Consumption
During Backwashing
(Watts): 8W 8W
Order Number 10628
S/N *2)
Infinity A
Type: 3/4" 1“ 1 1/4"
Nominal Size: DN20 DN25 DN32
Flow rate (litres per min):
Δp=20 kPa m³/h 4 5 5,5
Δp=50 kPa m³/h 7 7,5 9
Pressure Loss:
@ 200 kPa: 2,5 2,5 2,5
@ 500 kPa: 4,5 4,5 4,5
Nominal Pressure (kPa): 1600 1600 1600
Recommended Operating
Pressure Range (kPa): 300-600 300-600 300-600
Filter Efficiency (Micron): 90-110 90-110 90-110
Operating Temperature (°C):
Water 5-30 5-30 5-30
Ambient 5-40 5-40 5-40
Power Consumption
During Backwashing
(Watts): 8W 8W 8W
Order Number 10627
S/N *2)
IMPORTANT NOTICE:
FOR THE CORRECT OPERATION AND MAINTENANCE OF THIS PRODUCT,
IT IS ESSENTIAL TO OBSERVE THE MANUFACTURER'S INSTRUCTIONS.
For further information please visit www.reece.com.au
Infinity A