iNetVu™ Service Manual Page 39 of 109
3.2.8. Calibration Related
3.2.8.1. Azimuth Calibration
Cause:
Azimuth requires re-calibration if
1) A new platform is used on a previously used controller, or if a new
controller is used on a previously used platform.
2) An Azimuth Calibration is also required if the Azimuth Pot Zero, or Pot
Factor have been changed due to switching between platforms in
configuration, or manual changes.
3) System is unable to find the Stow Limit near the Azimuth = 0 position.
Solution:
1. Go to Maintenance
2. Click Calibrate AZ
3.2.8.2. Polarization Calibration
Cause:
1) A new platform is used on a previously used controller, or if a new
controller is used on a previously used platform.
2) An Azimuth Calibration is also required if the Azimuth Pot Zero, or Pot
Factor have been changed due to switching between platforms in
configuration, or manual changes.
3) System is unable to find the Stow Limit near the Azimuth = 0 position.
Solution:
1. Switch to CONFIG mode.
2. Go to Maintenance
3. Click Calibrate PL