iNetVu™ Service Manual Page 47 of 109
To increase the UP Limit Angle (i.e. Switch turns on later), move the
magnetic bracket lower.
To decrease the UP Limit Angle (i.e. Switch turns on earlier), move the
magnetic bracket higher.
Down (DN) Limit Switch
The Elevation DN Limit Switch Indicator should be ON between:
0 - 10 for 0.74/0.95/0.98 Mobile Platforms
5 - 10 for 1.2 Mobile Platforms
1) Remove Elevation Cover.
2) Locate Elevation DN Limit Switch.
3) Start iNetVu Mobile Software.
4) Go to Advanced Controls.
5) Set Elevation to 12, Azimuth to 0, and Polarization to 0 in Manual Controls.
6) Click Deploy Dish.
7) Adjust the space between the Limit Switch and Magnet to 3-5 mm by loosening
the Locking Nuts and sliding the Limit Switch either closer to or further from the
Limit Switch, and also adjusting the position of the Magnet Block to help
accommodate the 3-5 mm gap.
Typically, there are approximately 4-5 threads of the Limit Switch exposed
on the base.
8) Set Duration to 10 and Speed to 5.
9) Click Elevation Down, until the Elevation DN Indicator comes ON.
10) If the Elevation Angle is not between the values stated above, raise the
Elevation and re-adjust the magnet block, by loosening the locking screws
until satisfactory results are met.
It is imperative to maintain the 3-5 mm gap between the Limit Switch and
Magnet at the Elevation at which the Elevation UP Indicator comes ON.
To increase the DN Limit Angle (i.e. Switch turns on later), rotate the
magnetic bracket away from the Limit Switch (clockwise).