9.1 Test Mode without Print Job
Warning!
In operation of the applicator movable parts are accessible. It is particularly in the area of belt and fans.
Do not reach into the zone of the moving parts and keep long hair, loose clothes, and jewelry distant.
2
1
Fig.9 Test mode via Enter key
Notice!
Pleaseusethattestmodetoadjusttheparameter"Peelposition"intheprinterconguration.
The whole labelling process can be simulated without the need of a print job or a connection to a computer by alter-
nately pressing the feed (2) key and the Enter key (1) :
Press the feed key (2).
A blank label is fed. The vacuum from the fans as well as the supporting air (blow tube) are switched on. After the
detectingthelabelfromreexsensor,thesupportingairisswitchedoff.
Press the Enter key (1).
The label will moved to the labelling position.
9.2 Test Mode with Print Job
Notice!
Please use that test mode to adjust the peel-off offset in the software.
That method allows to check labelling process with the real print data using the Enter key
(1).
Send a print job.
The test mode is executed in two half cycles :
Press the Enter key (1).
Half cycle 1
A label is printed. The vacuum from the fans as well as the supporting air (blow tube) are switched on. After the
label has been picked up by the applicator, the supporting air is switched off.
Press the Enter key (1) again.
Half cycle 2
The label will moved to the labelling position.
Ifthelabelismanuallyremovedafterthersthalfcycle,thehalfcycle1willberepeatedwhenthepre-dispensekey
is pressed again.