User's GUide — 53
(cont’d)
10. Find Conduit Size:
FMC 1.50 in COND SIZE
11. Find total number of Wires:
4. TTL WIRES
12. Find Conduit Fill Percent:
FILL 36.1 % COND
13. Find actual Fill Area:
FILL 0.6711 TTL WIRE AREA
14. Find Remaining Area:
REM 0.0717 WIRE AREA
* Wire size can also be entered in Circular Mils (e.g.,
5
enters 105,600 CMILs and displays 0 AWG
Wire Size; 
enters 66,360 CMILs and displays 2
AWG Wire Size).
CONVERTING KIlOWaTT-hOuR aND bTu
Find the equivalent BTU rating of a 3.5 kilowatt-hour rated furnace.
KEYSTROKE DISPLAY

0.
1. Enter kilowatt hours:

3.5
2. Find equivalent BTU:
(Kw-hrBtu)
BTU 11,953.552
What is the kilowatt-hour rating for a 4,500 BTU heater?
KEYSTROKE DISPLAY

0.
KEYSTROKE DISPLAY