CIRCUIT
2.5A
VALEURS DISJONCTEUR
COMPRESSEUR
1 ET 2
VENTILATEUR
1 ET 2
3.3A38.9A
96
96
TK
TK
6 (COM)(N/O) 4
5
1
3
L1
L2
L3
AB
4 (N/O)
6 (N/O)
3 (N/F)
10
11
(COM) 7
(COM) 9
AB
(N/F) 1
(N/O) 4 7 (COM)
B
B
4 (N/O)
(COM) 97 (COM)
A
A
1 (N/F)
4 (N/O)
34
(N/F) 33
A2A1
A1A2
A1 A2 (COM) 9
34
33 (N/F)
3 (N/F)
6 (N/O)
A1A2
44
(N/F) 43
AB 15 (COM)
A1A2
1
3
5
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
A2A1
(N/O) 2
(N/O) 4
(N/O) 6
1
3
5
6
5
44
C (COM)
L (N/O)
C (COM)
H (N/O)
U
V
W
U
V
W
13 (AUX)(N/O) 14
AB
(COM) C
(N/O) H
L (N/F)
(COM) C
(N/O) H
L (N/F)
6 (N/O)
9 (COM)
AB
4 (N/O)
7 (COM)
8
7
13 (AUX)(N/O) 14
TEMPORISATION
1
12 HEURES
BORNES
D'ECLENCHEMENT
PRESSOSTAT EAU
RELAIS (R3)
RELAIS (R1)
RELAIS (R5)
CIRCUIT
FRIGORIFIQUE
1 THERMOSTAT
DE DEGIVRAGE
TEMPORISATION
2
6 MINS
RELAIS (R7)
RELAIS (R6)
DISJONCTEUR
COMMANDE
MONITEUR DE
PHASES
RECHAUFFEUR
COMP 2
DEMARRAGE AMORTI
DISJONCTEUR
THERMIQUE ET
VOYANT DE DEFAUT
SI INSTALLE
DEMARREUR OU
CONTACTEUR
DE DEBIT
CONTACTEUR COMP 2
CONTACTEUR COMP 1
DISJONCTEUR COMP 1
DISJONCTEUR COMP 2
ELECTROVANNE
(ARRET LIGNE LIQUIDE)
CIRCUIT 1
ELECTROVANNE
(ARRET LIGNE LIQUIDE)
CIRCUIT 2
TEMPORISATION
3
7 MINS
THERMOSTAT 2 CANAUX
CIRCUIT
FRIGORIFIQUE
2
DE DEGIVRAGE
SONDE
CONTACT 7 ET 8 FERMES EN MODE FROID
CONTACT 4 ET 6 FERMES EN MODE CHAUDE
VOYANT
DEFAUT
VOYANT
DEBIT D'EAU
VOYANT CHAUFFAGE
VOYANT
TEMP OK
VOYANT
REFROIDISSEMENT
VOYANT
REFROIDISSEMENT
VOYANT ALIMENTATION
PRINCIPALE
VOYANT
DEGIVRAGE
COMMUTATEUR
VEILLE
(MARCHE) (I)
2
3
(VEILLE) (O)
(N/F)
COMP 1 AUX
(DISJONCTEUR)
PROTECTION
ELECTRONIQUE
COMPRESSEUR 1
CONTACT ALARME DISJONCTEUR
COMPRESSEUR 1
CONTACT ALARME
DISJONCTEUR COMPRESSEUR 2
PROTECTION
ELECTRONIQUE
COMPRESSEUR 2
COMPRESSEUR 2
PRESSOSTAT BP
(SE COUPE A H EN BASSE PRESSION)
COMPRESSEUR 2
PRESSOSTAT HP
(SE COUPE A L EN HAUTE PRESSION)
COMPRESSEUR 1
PRESSOSTAT BP
(SE COUPE A H EN BASSE PRESSION)
COMPRESSEUR 1
PRESSOSTAT HP
(SE COUPE A L EN HAUTE PRESSION)
CIRCUIT FRIGORIFIQUE
2
SOUPAPE D'INVERSION
CIRCUIT FRIGORIFIQUE 1
SOUPAPE D'INVERSION
CONTACT ALARME
DISJONCTEUR VENTILATEUR 2
CONTACT ALARME
DISJONCTEUR VENTILATEUR 1
VENTILATEUR 2
PROTECTION
THERMIQUE
VENTILATEUR 1
PROTECTION
THERMIQUE
CONTACTEUR
VENTILATEUR 2
VENTILATEUR 1
DISJONCTEUR VENTILATEUR 2
VENTILATEUR 2
CONTACTEUR
VENTILATEUR 1
DISJONCTEUR VENTILATEUR 1
(SE COUPE A 'H' EN
BASSE DE TEMPERATURE )
CIRCUIT FRIGORIFIQUE 2
PRESSOSTATS LIMITE DE
REFROIDISSEMENT
CIRCUIT FRIGORIFIQUE 1
(SE COUPE A 'H' EN
BASSE DE TEMPERATURE )
L1 L2 L3
14 (N/O)
(N/F) 95
(N/F) TK
(COM) 1
1 (L)
(N) 2
(N/F) 5
2 (N/F)
4
(N/F)
6
(N/F)
11 (COM)
12 (N/F)
1 (N/F)
(COM) C
(N/O) H
L (N/F)
(SE COUPE A H
EN BASSE
TERMERATURE)
1 (N/F)
(COM) 7
3 (N/F)
6 (N/O)
(N/O) 4
(N/F) 1
(COM) C
(N/O) H
L
(N/F)
(COM) 7
15 (COM)
18 (N/O)
16 (N/F)
COMPRESSOR 1
CONTACTEUR
COMPRESSOR 2
CONTACTEUR
15 (COM)
16 (N/F)
18 (N/O)
(COM) C
(N/O) L
H (N/F)
(COM) C
(N/O) H
L
(N/F)
18 (N/O)
16 (N/F)
(N/F) 2
(N/F) 4
(N/F) 6
CIRCUIT
2
VOYANT
DEFAUT
CIRCUIT 1
VOYANT
DEFAUT
1
2
1
3
5
(N/F) 2
(N/F) 4
(N/F) 6
1
3
5
A2A1
1
3
5
(N/F) 2
(N/F) 4
(N/F) 6
COMP
1
21 (AUX)
(N/O) 2
(N/O) 4
(N/O) 6
(N/F) 22
1
3
5
(N/F) 2
(N/F) 4
(N/F) 6
COMP
2
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
21 (AUX)
(N/F) 22
43
(N/F)
H (N/F)
L (N/F)
(N/F) 1
(N/O) 4
7 (COM)
7 (COM)
(N/O) 8
(N/F) 9
3 (N/F)
(N/F)
1 (N/F)
(N/F)
(N/F)
OUT 1
OUT 2
WATER FLOW SWITCH CONTACTS SHOWN WITH WATER FLOW AT MAXIMUM RATE
MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON CONDITION
ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED
WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY
NOTE
RECHAUFFEUR
COMP 2
RELAIS (R2)
RELAIS (R4)
CIRCUIT
FRIGORIFIQUE 1
CIRCUIT
FRIGORIFIQUE 2
CIRCUIT
FRIGORIFIQUE 2
THERMOSTAT
DE DEGIVRAGE
(SE COUPE A H
EN BASSE
TEMPERATURE)
COMP 2 AUX
(DISJONCTEUR)
PP90(T)EHC TRIPHASEE (200V ~ 3 60Hz)
(N/F) 95
(N/F) TK
23
SD566250 ISSUE 35