ESC < > ENTER
I
ESC < > ENTER
2
a
< >
<
<
>
>
ESC < > ENTER
---
M2M1
ESC < > ENTER
oP2
M2M1
ESC < > ENTER
oP I
Page 25 - Manual code:
119DW02EN
vers. 3 03/2014 © CAME Cancelli Automatici S.p.A. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.A.
Select A 2.
Press ENTER to confirm.
Select 1 to activate the test.
Press ENTER to confirm...
...“---” appears while waiting for the command.
Hold down the key marked with the arrow > and
check that the second gearmotor leaf (M2) performs
an opening manoeuvre.
N.B. if the leaf performs a closing manoeuvre,
reverse the motor phases.
Perform the same procedure with the key marked
with the arrow< to check the leaf on the first
gearmotor (M1).
N.B. if the leaf performs a closing manoeuvre,
reverse the motor phases.