04 & &#
&!
%


#
#
p.
13
13 - Manual code:
FA01036-EN
FA01036-EN v.
1
- 01/2018 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
Power supply
Terminals for powering up accessories:
- a 24 V AC normally;
- a 24 V DC when the emergency batteries are operating;
Overall allowed power: 40 W
230 V AC - 50/60 Hz
24 V DC gearmotor
Factory wiring
Warning devices
COM
NC
NC
COM
Closing micro switch
Orange
Orange
White
Red
Blue
Brown
Opening micro
switch
Eyelet with screw and washer for
ground connection
Barrier indicator light (contact rated for: 24 V AC - 3 W max).
it warns of the booms raised position, and switches off when the boom is lowered.
Dome flashing light and/or luminous cord (Contact
rated for: 24 V - 32 W max.)
It flashes during the boom's opening and closing
phases.
The gearmotor is already connected.
To install the barrier on the right, follow the instructions in the PREPARING THE BARRIER.

Other manuals for CAME GARD 8 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME GARD 8 SERIES and is the answer not in the manual?

CAME GARD 8 SERIES Specifications

General IconGeneral
ModelGARD 8 SERIES
TypeAutomatic Barrier
Motor voltage24 V DC
Power300 W
Operating temperature-20°C to +55°C
Protection ratingIP54
Input Voltage230 V AC
Output Voltage24 V DC
Protection DegreeIP54
Power supply230 V AC
Opening time4 to 8 seconds