New user
Register up to a maximum of 250 users and assign a function to each one.
The operation can be carried out by using a transmitter or another control device. The boards that manage the control devices (AF - R700 - R800) must
be inserted into the connectors.
U1 1 = Step-by-step
The first command is to open and the second to close.
2 = Sequential
The first command is to open, the second to STOP, the third to close and the fourth to STOP.
3 = Open
4 = Partial opening
Choose the function to be assigned to the user.
Press ENTER to confirm.
The free position in the memory is shown intermittently for a maximum of 10 seconds. During this phase, send the
code from the control device.
Repeat the procedure to add other users.
Remove user
Remove one of the registered users.
U2 No. 1 > 250
Use the arrows to choose the number associated with the user you want to remove.
Alternatively, the control device associated with the user you want to remove can be activated.
Press ENTER to confirm.
“CLr” will appear to confirm deletion.
Remove all
Remove all registered users.
U3 OFF (Cancel operation)
ON (Run operation)
Radio decoding
Choose the type of radio coding for the transmitters enabled to control the operator.
If you choose the type of radio coding for the transmitters [Rolling code] or [TW key block], any transmitters with a different type of radio coding saved
previously will be deleted.
U4 1 = All decoding (default)
2 = Rolling code
3 = TW key block
Motor force
Set the motor force during opening.
A1 1 = Standard force (Default)
The motor guarantees a maximum lift of 20 kg beyond the necessary lifting of the door.
2 = Double force
The maximum lift is 40 kg beyond the necessary lifting of the window/door.
For private installations only.
Motor test
Check the gearmotor rotates in the correct direction.
A2 Press the < key to run an opening manoeuvre.
Press the > key to run a closing manoeuvre.
Travel calibration
Start the travel self-learning.
During calibration, all safety devices are disabled, except for the STOP button [F1 – Total stop].
A3 OFF (Cancel operation)
ON (Run operation)
Parameter reset
Restores the factory settings, including the travel calibration settings.
A4 OFF (Cancel operation)
ON (Run operation)