Page 22 - Manual FA01768-EN - 07/2022 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
RSE communication
Enable CRP.
F49 OFF
3 = CRP/CAME KEY (Default)
Save data
Save user data, timings and configurations to the memory device (memory roll).
The function is displayed only when a memory roll card is inserted into the control board.
F50 OFF (Default)
ON (Run operation)
Read data
Upload user data, timings and configurations to the memory device (memory roll).
The function is displayed only when a memory roll card is inserted into the control board.
F51 OFF (Default)
ON (Run operation)
CRP address
Assign a unique identification code (CRP address) to the control board.
F56 from 1 to 255
RSE speed
Set the remote connection system communication speed on the RSE port.
F63 0 = 1200 bps
1 = 2400 bps
2 = 4800 bps
3 = 9600 bps
4 = 14400 bps
5 = 19200 bps
6 = 38400 bps (default)
7 = 57600 bps
8 = 115200 bps
RIO ED T1 and RIO ED T2
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
F65
F66
OFF (Default)
P0 = It stops the gate and excludes automatic closing. Use a control device to resume movement.
P7 = Reopen while closing.
P8 = Reclose while opening.
RIO PH T1 and RIO PH T2
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
F67
F68
OFF (Default)
P1 = Reopen while closing.
P2 = Reclose while opening.
P3 = Partial stop.
P4 = Obstacle standby.