8
8
8-235
8-235
COPIER > FUNCTION > INSTALL
INISET-C Exe of C Dev Ass'y initial install mode
Lv.1 Details To automatically execute operation necessary for initial
installation of the C Developing Assembly.
1. Idle rotation of the Developing Assembly
2. Initialization of the Toner Density Sensor
3. Secondary transfer ATVC control
4. Patch light intensity correction
5. Background correction
6. Discharge current control
7. Primary transfer ATVC control
8. Initialization of the Patch Sensor
9. Auto registration
10. D-max control
11. D-half control
12. ARCDAT-Lite (creates the target)
13. Cleaning of the Secondary Transfer Outer Roller (twice)
14. Counter reset of the Developing Assembly
Use case When replacing the C Developing Assembly
Adj/set/operate method Select the item, and then press OK key.
Caution When installing the machine or replacing the Developing
Assembly of other color, do not use this item. .
Execute this item after setting "AINR-OFF" to "1: ON".
•
•
Display/adj/set range During operation: xxx second (remaining time), At normal
termination: OK, At abnormal termination: NG
Unit -
Appropriate target value -
Default value -
Required time 155 seconds
Related service mode COPIER> FUNCTION> INSTALL> INISET-Y, INISET-M,
INISET-K, INISET-4, AINR-OFF
Related user mode -
Supplement/memo -
COPIER > FUNCTION > INSTALL
AINR-OFF ON/OFF of warm-up rotation deactivation
Lv.1 Details To set ON/OFF to disable execution of warm-up rotation.
Warm-up rotation can be omitted when turning OFF/ON the
power to check the image, etc. after the adjustment of warm-up
rotation, etc. This mode is executed when warm-up rotation is
not needed.
Use case At installation
When replacing the Developing Assembly
•
•
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution Be sure to enable the operation (cancel disabling) before the
machine is used by the user. The operation is automatically
enabled by executing INISET-Y/M/C/K/4.
Display/adj/set range 0 to 1
0: OFF (Warm-up rotation enabled), 1: ON (Warm-up rotation
disabled)
Unit -
Appropriate target value -
Default value 0
Required time -
Related service mode COPIER> FUNCTION> INSTALL> INISET-Y, INISET-M,
INISET-C, INISET-K, INISET-4
Related user mode -
Supplement/memo -
E-RDS Set use/no use of Embedded-RDS function
Lv.1 Details To set whether to use the Embedded-RDS function.
Use case When using Embedded-RDS
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG
and RGW-ADR as a set.
Display/adj/set range 0 to 1
0: Function not used, 1: Function used (All the counter
information is sent.)
Unit -
Appropriate target value -
Default value 0
Required time -
Related service mode COPIER> FUNCTION> INSTALL> RGW-PORT, COM-TEST,
COM-LOG, RGW-ADR
Related user mode -
Supplement/memo Embedded-RDS: Function to send device information such as
the device counter, failure, and consumables etc. to the sales
company's server via SOAP protocol