8
8
8-242
8-242
COPIER > FUNCTION > DPC
DRMRSETC Forcible exe of C Drum replacement mode
Lv.1 Details When replacement of Drum Unit is completed within 30 minutes,
warm-up rotation may not be executed at power-off/on because
of high xing temperature. In such cases, drum potential
becomes unstable, causing an image failure to occur. To prevent
this symptom, this item forcibly executes the same operation
as warm-up rotation. At this time, laser power values, etc., that
were corrected according to C drum counter, total charging time,
target Vd values for potential control and drum durability are
reset.
Use case When detection of the Drum Unit replacement has failed
When the Drum Unit used in other machine for a while is used
as a dummy unit
•
•
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
When the drum replacement mode is enabled, it becomes
disabled automatically after execution.
Caution Use a Drum Unit that is not close to the end of life as a dummy
unit. When using a Drum Unit that is close to the end of life, it
affects the life of developer, etc.
Display/adj/set range 0 to 1
0: Disabled (Not executed), 1: Enabled (Executed)
Unit -
Appropriate target value -
Default value 0
Required time Approx. 2 minutes
Related service mode COPIER> FUNCTION> DPC> DRM-RSET, DRMRSETY,
DRMRSETM, DRMRSETK
Related user mode -
Supplement/memo -
COPIER > FUNCTION > DPC
DRMRSETK Forcible exe of Bk Drum replacement mode
Lv.1 Details When replacement of Drum Unit is completed within 30 minutes,
warm-up rotation may not be executed at power-off/on because
of high xing temperature. In such cases, drum potential
becomes unstable, causing an image failure to occur. To prevent
this symptom, this item forcibly executes the same operation as
warm-up rotation. At this time, laser power values, etc., that were
corrected according to Bk drum counter, total charging time,
target Vd values for potential control and drum durability are
reset.
Use case When detection of the Drum Unit replacement has failed
When the Drum Unit used in other machine for a while is used
as a dummy unit
•
•
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
When the drum replacement mode is enabled, it becomes
disabled automatically after execution.
Caution Use a Drum Unit that is not close to the end of life as a dummy
unit. When using a Drum Unit that is close to the end of life, it
affects the life of developer, etc.
Display/adj/set range 0 to 1
0: Disabled (Not executed), 1: Enabled (Executed)
Unit -
Appropriate target value -
Default value 0
Required time Approx. 2 minutes
Related service mode COPIER> FUNCTION> DPC> DRM-RSET, DRMRSETY,
DRMRSETM, DRMRSETC
Related user mode -
Supplement/memo -
T-8-37