PC-D320/PC-D340/FAX-L400 Chapter 4: Maintenance and Service
4-21
No. Tx or Rx Definition
##0780 [TX ] In ECM transmission, no significant signal can be received after
transmission of EOR-EOM, and the allowed number of
procedure signal re-transmissions was exceeded
##0782 [TX ] In ECM transmission, DCN was received after transmission of
EOR-EOM
##0783 [TX ] In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of EOR-EOM
##0784 [TX ] In ECM transmission, ERR was received after transmission of
EOR-EOM
##0785 [TX ] In ECM transmission, no significant signal can be received after
transmission of EOR-EOP, and the allowed number of
procedure signal re-transmissions was exceeded
##0787 [TX ] In ECM transmission, DCN was received after transmission of
EOR-EOP
##0788 [TX ] In ECM transmission, the allowed number of procedure signl re-
transmissions was exceeded or a T5 time-over (60 sec) condition
occurred after transmission of EOR-EOP
##0789 [TX ] In ECM transmission, ERR was received after transmission of
EOR-EOP
##0790 [RX ] In ECM receprion, ERR was transmitted after reception of
EOR-Q
##0791 [TX/RX] During an ECM mode procedure, a signal other than a
significant signal was received
##0792 [RX ] In ECM reception, PPS-NULL between partial pages cannot be
detected
##0793 [RX ] In ECM reception, no effective frame was detected while signals
were received at high speed, and a time-over condition occurred
##0795 [TX/RX] A fault occurred in decoding process during a communication
##0799 [TX ] System error
No. Definition
New E000 Fixing unit failure
New E100 Scanner unit failure
New E805 Fan failure