PC-D320/PC-D340/FAX-L400 Chapter 4: Maintenance and Service
4-53
5.6 New SSSWs/Parameters Added to this Model
#1 SSSW
SW01 (service soft switch 01: error management )
Bit Function 1 0
0 Service error code Output Not output
1 Error dump list Output Not output
2 Enter password at confidential No Ye s
Rx image data transfer
3 Copy function No Ye s
4 (New) ##300 series service error code Output Not output
5 Not used
6 Date & Time setting restriction
Setting restricted Setting possible
7 User setting restriction
Setting possible Setting restricted
[Bit 4]
When “Output” is selected, ##300 series Service error codes are displayed and in reports.
When “Not output” is selected, no Service error codes are displayed.
SW28 (service soft switch 28: V.8/V.34 protocol settings)
Bit Function 1 0
0 (New) Caller V.8 protocol No Yes
1 (New) Called party V.8 protocol No Yes
2 (New) Caller V.8 protocol late start No Yes
3 (New) Called party V.8 protocol late start No Yes
4 (New) V.34 reception fallback Prohibited Not prohibited
5 (New) V.34 transmission fallback Prohibited Not prohibited
6 Not used
7 Not used
[Bit 0]
Select whether to use the V.8 protocol when calling. If “NO” is selected, the V.8 protocol
is inhibited at calling and the V.21 protocol is used.
[Bit 1]
Select whether to use the V.8 protocol when called. If “NO” is selected, the V.8 protocol
is inhibited when called and the V.21 protocol is used.