3 = Preset Weight Comparators, Cont.
The relay state is based on using Cardinal Scale relays (p/n 6850-1013). If
using relays other than those supplied by Cardinal Scale, refer to the relay
manufacturers specifications. NOTE! When power to the indicator is lost, the
output returns to a Low State condition.
If
OUTPUTS=
2 through 8 or 12 through 18, advance to
WT RANGES=
If
OUTPUTS=
(1 or 11)
BAL PRNT
(YES = Enabled, NO = Disabled)
4 = Checkweigher
OUTPUTS
(Allowable values are 3 or 5)
If
OUTPUTS = 3
(All are Low State before cutoff (Relay* Open))
Over
Under
Accept
If OUTPUTS = 5 (All are Low State before cutoff (Relay* Open))
Over
High-Accept
Accept
Low-Accept
Under
The relay state is based on using Cardinal Scale relays (p/n 6850-
1013). If using relays other than those supplied by Cardinal Scale, refer
to the relay manufacturers specifications. NOTE! When power to the
indicator is lost, the output returns to a Low State condition.
AUTO PRNT (YES = Auto Print ON, NO = Auto Print OFF)
5 = Batcher
SPEED (1 = Single, 2 = Two Speed)
If (SPEED =1), advance to AUTO TRIM=
If (
SPEED =2
),
GATE SEQ
(1 = AB then B, 2 = A then B)
AUTO TRIM
(YES = Auto Trim ON, NO = Auto Trim OFF)
BIN COUNT
(Allowable values are 1 through 7)
If
SPEED=1
, up to 7 bins are available.
If
SPEED=2
, a maximum of 3 bins are available.
AUTO PRNT
(YES = Auto Print ON, NO = Auto Print OFF)
DUMP GATE
(
YES
= Enabled,
NO
= Disabled)
If
DUMP GATE = NO
, advance to
DCUMLATE =
If DUMP GATE = YES,
AUTO DUMP
(YES = Enabled, NO = Disabled)
DCUMULATE
(YES =Weigh Out, NO = Weigh In)
WT RANGES
(1 = Single Interval, 2 = Dual Interval)
If WT RANGES = 1 advance to the INTERVAL.
If WT RANGES = 2
LOW INT
If
LFT=YES
(Allowable values are: 1, 2, 5, 10, 20 or 50).
If
LFT=NO
(Allowable values are: 1 through 99).
LOW DPP
(Allowable values are 0, 1, 2 or 3).
0 = XXXXXX 1= XXXXX.X 2 = XXXX.XX 3 = XXX.XXX