GRX INFUSION TIME OUT (41, 42, 43)
This alarm appears 120 seconds after the alarm “GRX VOLUMETRIC METER
SIGNAL” appears.
GRX INFUSION T.O.
CAUSE CONSEQUENCE POSSIBLE SOLUTION
Co󰀨ee brewing time is
greater than 120 sec-
onds.
The machine turns
OFF.
In the event that the co󰀨ee is not dispensed,
check:
The presence of mains water.
The ltering sy󰀬em / softening sy󰀬em
of the incoming water and the various
lters.
The cleaning conditions of the unit.
If the problem persi󰀬s, contact Technical
Support.
STEAM WAND TEMPERATURE (36)
STEAM NOZZLE
TEMPERATURE
CAUSE CONSEQUENCE POSSIBLE SOLUTION
The temperature read
by the 󰀬eam wand
sensor is out of range:
greater than 141° C.
less than 0° C
(unlikely situation;
sensor failure).
The 󰀬eam wand works
without the control of
the temperature probe.
Press the button to 󰀬art the 󰀬eam and
press it again to 󰀬op the ow.