GRX INFUSION TIME OUT (41, 42, 43)
This alarm appears 120 seconds after the alarm “GRX VOLUMETRIC METER
SIGNAL” appears.
GRX INFUSION T.O.
CAUSE CONSEQUENCE POSSIBLE SOLUTION
Coee brewing time is
greater than 120 sec-
onds.
The machine turns
OFF.
In the event that the coee is not dispensed,
check:
● The presence of mains water.
● The ltering syem / softening syem
of the incoming water and the various
lters.
● The cleaning conditions of the unit.
If the problem persis, contact Technical
Support.
STEAM WAND TEMPERATURE (36)
STEAM NOZZLE
TEMPERATURE
CAUSE CONSEQUENCE POSSIBLE SOLUTION
The temperature read
by the eam wand
sensor is out of range:
● greater than 141° C.
● less than 0° C
(unlikely situation;
sensor failure).
The eam wand works
without the control of
the temperature probe.
Press the button to art the eam and
press it again to op the ow.