EasyManua.ls Logo

Carimali DIVAPro - Page 46

Carimali DIVAPro
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46
GRX LOW TEMPERATURE
This alarm does not have a numeric code.
LOW GRX TEMPERATURE
CAUSE CONSEQUENCE POSSIBLE SOLUTION
The temperature of the
unit read by the sensor
is lower than 10° C.
None.
Wait for the unit to return to the set
temperature.
Check the supplied water quantity.
ADJUSTMENT FOR COARSER GRINDING
This alarm does not have a numeric code.
ADJUST GRINDER COARSE
CAUSE CONSEQUENCE POSSIBLE SOLUTION
With the CHRONO
function enabled, the
set brewing time is
greater than the actual
brewing time (including
tolerance).
Extraction problem /
scarce co󰀨ee spilling
from the lter holder.
Check / calibrate the co󰀨ee grinding.
Clean the sprayhead and lter.
Check the quantity of co󰀨ee introduced
in the lter.
ADJUSTMENT FOR FINER GRINDING
This alarm does not have a numeric code.
ADJUST GRINDER FINE
CAUSE CONSEQUENCE POSSIBLE SOLUTION
With the CHRONO
function enabled, the
set brewing time is
greater than the actual
brewing time (without
tolerance).
Abundant ow of
co󰀨ee exiting the lter
holder.
Check / calibrate the co󰀨ee grinding.
Check the quantity of co󰀨ee introduced
in the lter.

Related product manuals