112 Specications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 13/12/2017
P(11-18)
I(11-19)
+
-
Frequency
Reference
Speed
Observer
Feedback
D(11-20)
+
+
+
Torque
Reference
Torque
Limit
12 Monitor function group
12-00 Display Mode
Range
0 0 0 0 0
MSD LSD
00000~77777 / Each digit can be set from 0 to 7 as listed below.
[0]: Disable display
[1]: Output current
[2]: Output voltage
[3]: DC voltage
[4]: Temperature of Heat Sink
[5]: PID feedback
[6]: AVI
[7]: ACI
MSD= Most significant digit. LSD= Least significant digit.
Note: MSD of parameter 12-00 sets the power on display, other digits set user selected
displays. (refer to P4-4).
Set motor rated RPM in this parameter if required then the display will show this value
when inverter output frequency reaches the motor name plate frequency. 50Hz or 60 Hz as
appropriate.
The line speed display is linearly proportional to the output frequency 0 to 50Hz or 0-60 Hz as
appropriate. Motor synchronous speed = 120 x Rated frequency/Number of poles.
12-01 PID Feedback Display Mode
Range
[0] Displayed in integer (xxx)
[1] Displayed with one decimal place (xx.x)
[2] Displayed with two decimal places (x.xx)
12-02 PID Feedback Display Unit Setting
Range
[0] xxx
[1] xxxpb (pressure)
[2] xxxfl (flow)
12-03 Custom Units (Line Speed) Value
Range [0~65535] rpm