EasyManuals Logo

CARLO GAVAZZI VariFlex3 RVLF Series User Manual

CARLO GAVAZZI VariFlex3 RVLF Series
245 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #142 background imageLoading...
Page #142 background image
Motor Controllers AC Variable Frequency Drives Type VariFlex
3
RVLF
138 Specications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 13/12/2017
NOTICE
Observe proper electrostatic discharge procedures (ESD) when handling the drive and circuit boards.
Failure to comply may result in ESD damage to the drive circuitry.
Never connect or disconnect the motor from the drive while the drive is outputting voltage.
Improper equipment sequencing could result in damage to the drive.
Do not use unshielded cable for control wiring.
Failure to comply may cause electrical interference resulting in poor system performance. Use shielded twisted-
pair wires and ground the shield to the ground terminal of the drive.
Do not modify the drive circuitry.
Failure to comply could result in damage to the drive and will void warranty.
Carlo Gavazzi is not responsible for any modication of the product made by the user. This product must not be
modied.
Check all the wiring to ensure that all connections are correct after installing the drive and connecting
any other devices.
Failure to comply could result in damage to the drive.
UL Standards
The UL/cUL mark applies to products in the United States and Canada and it means that UL
has performed product testing and evaluation and determined that their stringent standards
for product safety have been met. For a product to receive UL certication, all components
inside that product must also receive UL certication.
UL Standards Compliance
This drive is tested in accordance with UL standard UL508C and complies with UL requirements.
To ensure continued compliance when using this drive in combination with other equipment,
meet the following conditions:
Installation Area
Do not install the drive to an area greater than pollution severity 2 (UL standard).
Main Circuit Terminal Wiring
UL approval requires crimp terminals when wiring the drive’s main circuit terminals. Use
crimping tools as specied by the crimp terminal manufacturer. Carlo Gavazzi recommends
crimp terminals made by NICHIFU for the insulation cap.
The table below matches drives models with crimp terminals and insulation caps. Orders
can be placed with a Carlo Gavazzi representative or directly with the Carlo Gavazzi sales
department.

Table of Contents

Other manuals for CARLO GAVAZZI VariFlex3 RVLF Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CARLO GAVAZZI VariFlex3 RVLF Series and is the answer not in the manual?

CARLO GAVAZZI VariFlex3 RVLF Series Specifications

General IconGeneral
BrandCARLO GAVAZZI
ModelVariFlex3 RVLF Series
CategoryController
LanguageEnglish