Motor Controllers AC Variable Frequency Drives Type VariFlex
3
RVLF
160 Specications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 13/12/2017
Table 4.3 – Analog output property list (READ/ WRITE)
No.
Object
Name
Description Unit Classication Range
AO0 Set Frequency
Frequency
command
HZ R/W 0 - 599
AO1 AO Output voltage Volt R 0 - 10
AO3 Motor R-Amp Motor rated current Amps R/W 0-65535
AO4 PwrL Sel
Momentary stop and
restart selection
No Units R 0 - 1
AO5 RestartSel
Number of Fault Auto-
Restart Attempts
No Units R 0 – 10
AO6 RestartDelay
Fault Auto-
Restart Time
seconds R 0 - 800
AO7 FreqCommand1
Speed frequency
setting-stage 0
HZ R/W 0 - 599
AO8 FreqCommand2
Speed frequency
setting-stage 1
HZ R/W 0 - 599
AO9 FreqCommand3
Speed frequency
setting-stage 2
HZ R/W 0 - 599
AO10 FreqCommand4
Speed frequency
setting-stage 3
HZ R/W 0 - 599
AO11 FreqCommand5
Speed frequency
setting-stage 4
HZ R/W 0 - 599
AO12 FreqCommand6
Speed frequency
setting-stage 5
HZ R/W 0 - 599
AO13 FreqCommand7
Speed frequency
setting-stage 6
HZ R/W 0 - 599
AO14 FreqCommand8
Speed frequency
setting-stage 7
HZ R/W 0 - 599
AO23 RunMode
Main run command
source selection
No Units R/W 0 - 2
AO24 ReverseOper
Direction locked
command
No Units R/W 0 - 1
AO25 StoppingSel
Stop modes
selection
No Units R/W 0 - 1
AO26 FrequenceComm
Main frequency com-
mand source selection
No Units R/W 0 - 6
AO27 FreqUpperLim
Upper limit
frequency
HZ R/W 0.01 - 599
AO28 FreqLowerLim
Lower limit
frequency
HZ R/W 0 – 598.99
AO29 Acc Time1 Acceleration time 1 seconds R/W 0.1 - 3600
AO30 Dec Time1 Deceleration time 1 seconds R/W 0.1 - 3600