default display, the operator would only have to press
to display the same data again.
Table 2-7 Unit Data Codes
The suction pressure is displayed with the descrip-
unit designator P (psig) or B (Bars) (i.e. SUCT 25P) .
The display is in inches of mercury for readings below
0 psig. The display range is --0.7 Bars to 6.9 Bars (--20
The number of diesel engine hours are displayed
5040H). The display range is 0 to 99999.
The coolant temperature is displayed with the des-
CD4: Compartment 1 Return Air Temperature
with the description 1RA or CD4. The data is displayed
with one decimal place and the proper unit designator,
Degree C or Degree F (i.e. RAS 85.0F). The display
CD6: Compartment 2 Defrost Thermistor Sensor
Compartment 2 Defrost Thermistor Sensor is dis-
CD7: Compartment 3 Defrost Thermistor Sensor
Compartment 3 Defrost Thermistor Sensor is dis-
CD8: Compartment 1 Defrost Thermistor Sensor
Compartment 1 Defrost Thermistor Sensor is dis-
CD9: Compressor Discharge Temperature
with the description CDT or CD9. The data is displayed
with the proper unit designator, Degree C or Degree F,
(i.e. CDT 85F) . The display range is --40
F). If the sensor is absent, then the dis-
play will read “------” for the data.
The battery voltage is display
BATT or CD10. The data is displayed with one decimal
place and then the letter “V” for volts (i.e. BATT 12.2V
or CD10 12.2V). The voltage reading is displayed with
a “+” (plus) sign if the battery status is good.
The number of electric motor hours are displayed
in hours and units designator “H” (i.e. SBY 5040H or
CD11 5040H). The display range is 0 to 99999.